OPERATION PANELS A-133
7-7-6
Setting Screen
Function selection key
(SETTING)
[SETTING]
The screen consists of two pages.
The desired page can be called by pressing the page
selection keys.
The screen is used for setting "valid" of "invalid" for
changing the CAP and NC parameters and also for setting
"ON" or "OFF" for the input unit, tape format, sequence
stop and mirror image.
When changing the CAP parameters or NC
parameters, be sure to return the setting for
"CAP PARAMETER WRITE" and "NC
PARAMETER WRITE" to "0" (INVALID) after
changing them.
Setting of the CAP parameters and NC
parameters can be changed in the MDI mode with
the NC in the reset or emergency stop state.
<Sequence stop>
This function suspends execution of a program by setting
a program or sequence number.
Once the sequence stop is executed, setting is disabled.
Setting is also disabled when the
(RESET) key is
pressed.
SETTING
CAUTION
NOTE
RESET