OPERATION PANELS A-37
5-6-10
Auxiliary Function Lock
The auxiliary function lock function is made valid or invalid
on the OPERATION PANEL screen, which is displayed by
pressing the function selection key
(SETTING).
The valid and invalid status of the auxiliary
function lock function changes simultaneously
when the status is changed for either of turret 1
and turret 2.
<Auxiliary function lock function>
The auxiliary function lock function is used to select whether or not the M, S, and T (auxiliary
function) commands are executed in a program during automatic operation. It is used to check
the program in combination with the machine lock function.
<When the auxiliary function lock is valid>
In the auxiliary function lock mode, the M, S, and T codes specified in a program are ignored.
Note that the following M commands are executed: M00, M01, M02, M30, M98, M99
<When the auxiliary function lock is invalid>
M, S, and T (auxiliary function) commands are executed as specified in the program.
SETTING