A-96 OPERATION PANELS
7-3
Function Selection Key
(OFFSET)
The function selection key
(OFFSET) is used for setting the tool geometry/wear offset data
and the work coordinate system.
To change the display screen, press the soft-key
corresponding to the screen to be accessed.
<Functions>
1.
Offset amount input interlock function
This function sets valid/invalid status of offset amount input operations for tool geometry
offset data, tool wear offset data and work offset data in the MDI mode. To validate or
invalidate the input operation, set CAP parameters No. 140 or No. 142.
Contents of the interlock function is determined by the value set to the parameters as shown
below.
Set Value
CAP Parameter
No. 140
No. 142
0
Interlock function is invalid. (Input operation for tool geometry offset data,
tool wear offset data and work offset data is valid.)
1
Input operation for tool geometry offset data is invalid.
2
Input operation for tool wear offset data is invalid.
3
Input operation for tool geometry offset data or tool wear offset data is
invalid.
4
Input operation for work offset data is invalid.
5
Input operation for tool geometry offset data or work offset data is invalid.
6
Input operation for tool wear offset data or work offset data is invalid.
7
Input operation for tool geometry offset data, tool wear offset data and work
offset data is invalid.
8
Input operation for work offset
data
*1
is invalid.
—
9
Input operation for tool geometry
offset data or work offset data
*1
is
invalid.
—
10
Input operation for tool wear offset
data or work offset data
*1
is invalid.
—
OFFSET
OFFSET
Setup
Work coordinate system
Tool wear offset
Tool geometry offset