98
(2) Counting range of the ring counter
One of the following three counting ranges of the ring counter is determined by the relationship among CH
Present value (RWr10 to RWr11, RWr28 to RWr29), CH
Ring counter lower limit value (RWw10 to RWw11,
RWw28 to RWw29), and CH
Ring counter upper limit value (RWw12 to RWw13, RWw2A to RWw2B) at the
time when CH
Count enable command (RY24, RY3C) is turned on or when the preset/ replace function is
performed.
• Ring counter lower limit value
≤
Present value
≤
Ring counter upper limit value (This range is normally
used.)
• "Present value < Ring counter lower limit value" or "Ring counter upper limit value < Present value"
• Ring counter lower limit value = Ring counter upper limit value
Set the ring counter upper limit value and the ring counter lower limit value according to the condition "Ring
counter lower limit value
≤
Ring counter upper limit value". When CH
Count enable command (RY24, RY3C) is
turned off then on with the condition not satisfied, CH
Ring counter upper/lower limit value setting error (error
code:
210
H
) is stored in CH
Latest error code (RWr22, RWr3A) and counting does not start. To start counting,
set the ring counter upper limit value and the ring counter lower limit value according to the condition "Ring
counter lower limit value
≤
Ring counter upper limit value" and turn off then on CH
Count enable command
(RY24, RY3C). The OFF time must be longer than
Δ
T
1
.
For
Δ
T
1
, refer to Page 283, Appendix 4.