116
●
While CH
External preset/replace (Z Phase) request detection (RX23, RX3B) is on, values cannot be replaced by this
function as well as by CH
Preset/replace command (RY21, RY39). Turn off then on CH
External preset/replace (Z
Phase) request detection reset command (RY23, RY3B) to turn off CH
External preset/replace (Z Phase) request
detection (RX23, RX3B).
●
Have a
Δ
T
1
or longer interval after changing CH
Preset value setting (RWw14 to RWw15, RWw2C to RWw2D) until the
value is replaced because there are maximum of
Δ
T
1
delay until change in CH
Preset value setting (RWw14 to
RWw15, RWw2C to RWw2D) is reflected.
*1
●
To perform the preset/replace function continuously using the same coincidence output, have a
Δ
T
1
or longer interval.
The preset/replace function may not operate if there is not a
Δ
T
1
or longer interval.
*1
The following is the rough standard of an interval for performing the preset/replace function continuously using the same
coincidence output.
(|Point setting (Coincidence output 1 to 4)
*2
- Preset value setting|) > (Input pulse speed (pps)/1000)
●
When the preset/replace (at coincidence output) function is used under the condition where pulses are input in a counting
speed of 2Mpps or faster, a pulse count difference (plus one or minus one pulse) occurs. Use the function after checking
that the difference does not cause a problem for the system.
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
*2
Change this into Upper limit value setting (Coincidence output 1 to 4) or Lower limit value setting (Coincidence output 1
to 4) according to the comparison condition and the setting in which Coincidence output 1 to 4 turns on.