250
RY9
Initial data setting
request flag
• When this signal is turned on, all the remote registers (RWr) of the high-speed
counter module are cleared to 0.
• When this signal is turned on, all the following remote buffer memory areas are
cleared to 0.
• Channel assignment (Coincidence output 1 to 4) (address: 0600
H
)
• CH
Operation mode (address: 0620
H
, 0640
H
)
• CH
Selected counter function (address: 0621
H
, 0641
H
)
• For details of the ON/OFF timing of this signal, refer to Page 236, Appendix 1.1.
RY10
Reset command
(Coincidence output 1)
• Turn on this signal to turn off Coincidence output 1 to 4 (RX10 to RX13) and
coincidence output 1 to 4 terminals (EQU1 to EQU4).
• This signal is valid only when Coincidence Output Function (0) is selected in
Comparison output setting (address: 0100
H
) and Coincidence Output (00) is
selected in Coincidence output comparison condition setting (address: 0102
H
).
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RY11
Reset command
(Coincidence output 2)
RY12
Reset command
(Coincidence output 3)
RY13
Reset command
(Coincidence output 4)
RY14
Setting change request
(Coincidence output 1)
• Turn on this signal to reflect the changes of the following remote registers (RWw)
to the high-speed counter module in the coincidence output function.
• Point setting (Coincidence output 1 to 4)/Lower limit value setting (Coincidence
output 1 to 4) (RWw0 to RWw1, RWw4 to RWw5, RWw8 to RWw9, RWwC to
RWwD)
• Upper limit value setting (Coincidence output 1 to 4) (RWw2 to RWw3, RWw6 to
RWw7, RWwA to RWwB, RWwE to RWwF)
• For Coincidence output 1, when Setting change request (Coincidence output 1)
(RY14) is turned on, the changes of Point setting (Coincidence output 1)/Lower
limit value setting (Coincidence output 1) (RWw0 to RWw1) and Upper limit value
setting (Coincidence output 1) (RWw2 to RWw3) are reflected to the high-speed
counter module. After the setting value is reflected, Setting change completed
(Coincidence output 1) (RX14) turns on.
• For Coincidence output 2 to 4, each corresponding remote I/O signals and remote
register (RWw) are used.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY15
Setting change request
(Coincidence output 2)
RY16
Setting change request
(Coincidence output 3)
RY17
Setting change request
(Coincidence output 4)
RY1F
External power supply
monitor request flag
Turn on this signal to activate the external power supply monitoring function.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY20
CH1
Coincidence
output enable
command
• Turn on this signal to enable output to coincidence output 1 to 4 terminals (EQU1
to EQU4) in the coincidence output function.
• This signal is valid to all the coincidence output 1 to 4 terminals (EQU1 to EQU4)
assigned to the channel.
• Up to
Δ
T
1
*1
is taken until this signal has been turned on.
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RY38
CH2
Remote
output
(RY) No.
Signal name
Operation
timing
Description
t T
1*1
Controlled by the high-speed counter module
Controlled by the program
ON
ON
ON
OFF
OFF
OFF
1000
0
1
999
0
1000
1001
t
t
t
Point setting (Coincidence output 1 to 4)
(RWw0 to RWw1, RWw4 to RWw5,
RWw8 to RWw9, RWwC to RWwD)
Coincidence output 1 to 4
(RX10 to RX13)
Reset command
(Coincidence output 1 to 4)
(RY10 to RY13)
CH Present value
(RWr10 to RWr11, RWr28 to RWr29)