36
Main
module
RX10
Coincidence output 1
RY10
Reset command (Coincidence output 1)
RX11
Coincidence output 2
RY11
Reset command (Coincidence output 2)
RX12
Coincidence output 3
RY12
Reset command (Coincidence output 3)
RX13
Coincidence output 4
RY13
Reset command (Coincidence output 4)
RX14
Setting change completed
(Coincidence output 1)
RY14
Setting change request (Coincidence output 1)
RX15
Setting change completed
(Coincidence output 2)
RY15
Setting change request (Coincidence output 2)
RX16
Setting change completed
(Coincidence output 3)
RY16
Setting change request (Coincidence output 3)
RX17
Setting change completed
(Coincidence output 4)
RY17
Setting change request (Coincidence output 4)
RX18
Use prohibited
RY18
Use prohibited
RX19
Use prohibited
RY19
Use prohibited
RX1A
Use prohibited
RY1A
Use prohibited
RX1B
Use prohibited
RY1B
Use prohibited
RX1C
Use prohibited
RY1C
Use prohibited
RX1D
Use prohibited
RY1D
Use prohibited
RX1E
Use prohibited
RY1E
Use prohibited
RX1F
External power supply monitor state flag
(for extension output module)
RY1F
External power supply monitor request flag
(for extension output module)
RX20
Use prohibited
RY20
CH1 Coincidence output enable command
RX21
CH1 Preset/replace completion
RY21
CH1 Preset/replace command
RX22
Use prohibited
RY22
CH1 Count down command
RX23
CH1 External preset/replace (Z Phase) request
detection
RY23
CH1 External preset/replace (Z Phase) request
detection reset command
RX24
Use prohibited
RY24
CH1 Count enable command
RX25
CH1 Counter function detection
RY25
CH1 Selected counter function start command
RX26
CH1 Cam switch execute/PWM output
RY26
CH1 Cam switch execute command/PWM
output start command
RX27
CH1 Setting change completed
(Sampling counter/Periodic pulse counter)
RY27
CH1 Setting change request
(Sampling counter/Periodic pulse counter)
RX28
CH1 Update flag reset completed (Latch count
value/Sampling count value/Periodic pulse
count value)
RY28
CH1 Update flag reset command (Latch count
value/Sampling count value/Periodic pulse
count value)
RX29
CH1 Update flag (Latch count value/Sampling
count value/Periodic pulse count value)
RY29
Use prohibited
RX2A
CH1 Latch count value update flag reset
completed (Latch counter input terminal)
RY2A
CH1 Latch count value update flag reset
command (Latch counter input terminal)
RX2B
CH1 Latch count value update flag
(Latch counter input terminal)
RY2B
Use prohibited
RX2C
CH1 Update flag reset completed (Measured
frequency value/Measured rotation speed value)
RY2C
CH1 Update flag reset command (Measured
frequency value/Measured rotation speed value)
RX2D
CH1 Update flag (Measured frequency
value/Measured rotation speed value)
RY2D
Use prohibited
RX2E
Use prohibited
RY2E
Use prohibited
RX2F
Use prohibited
RY2F
Use prohibited
Module
type
Remote input signal direction: High-speed counter
module
→
Master/local module
Remote output signal direction: Master/local
module
→
High-speed counter module
Device
number
Description
Device
number
Description