159
CHAPTER 8 FUNCTIONS
8
8.15 Pulse Measurement F
unction
When the pulse measurement function is executed with CH
Function input terminal (FUNC1, FUNC2), the time to be taken
to update CH
Measured pulse value (Function input terminal) (RWr1C to RWr1D, RWr34 to RWr35) varies according to
the time set in "CH
Function input response time setting". (The same can be applied to the measurement with CH
Latch
counter input terminal (LATCH1, LATCH2) except the differences such as the setting items.)
(7) Pulse measurement difference between CH
Function input terminal (FUNC1,
FUNC2) and CH
Latch counter input terminal (LATCH1, LATCH2)
The pulse measurement same as CH
Function input terminal (FUNC1, FUNC2) can be applied to the
measurement with CH
Latch counter input terminal (LATCH1, LATCH2) except the difference of the terminals
for the pulse measurement and the setting items.
The following table lists the differences of the setting items between both terminals.
Input terminal, setting
item
Pulse measurement (with function
input terminal)
Pulse measurement (with latch
counter input terminal)
Terminals for the pulse
measurement
CH
Function input terminal
(FUNC1, FUNC2)
CH
Latch counter input terminal
(LATCH1, LATCH2)
Setting for pulse width to be
measured
CH
Pulse measurement setting (Function
input terminal) (address: 012A
H
, 014A
H
)
CH
Pulse measurement setting
(Latch counter input terminal)
(address: 012B
H
, 014B
H
)
Measured pulse value
CH
Measured pulse value (Function
input terminal) (RWr1C to RWr1D, RWr34
to RWr35)
CH
Measured pulse value
(Latch counter input terminal)
(RWr1E to RWr1F, RWr36 to RWr37)
Pulse measurement start
command
CH
Pulse measurement start command
(Function input terminal) (RY30, RY48)
CH
Pulse measurement start command
(Latch counter input terminal) (RY32, RY4A)
Pulse measurement flag
CH
Pulse measurement flag (Function
input terminal) (RWr20.b6, RWr38.b6)
CH
Pulse measurement flag (Latch counter
input terminal) (RWr20.b7, RWr38.b7)
Measured pulse value update
flag
CH
Measured pulse value update flag
(Function input terminal) (RX32, RX4A)
CH
Measured pulse value update flag
(Latch counter input terminal) (RX34, RX4C)
Measured pulse value update
flag reset command
CH
Measured pulse value update flag
reset command (Function input terminal)
(RY31, RY49)
CH
Measured pulse value update flag reset
command (Latch counter input terminal)
(RY33, RY4B)
Measured pulse value update
flag reset completed
CH
Measured pulse value update flag
reset completed (Function input terminal)
(RX31, RX49)
CH
Measured pulse value update flag reset
completed (Latch counter input terminal)
(RX33, RX4B)
Содержание NZ2GFCF-D62PD2
Страница 1: ......
Страница 2: ......
Страница 54: ...52 Memo ...
Страница 206: ...204 Memo ...
Страница 303: ......
Страница 304: ......