74
*1
For EQU1 to EQU4, the assignment to CH1 or CH2 can be changed.
(4) ON/OFF status of input signals
The ON/OFF status of input signals depends on external wiring and the logic setting.
The following table shows an example of CH
Function input terminal (FUNC1, FUNC2).
The ON/OFF status for other input signals is the same as CH
Function input terminal (FUNC1, FUNC2).
*1
Configure the logic setting by CH
Function input logic setting (address: 0127
H
, 0147
H
). For details on the setting, refer
to the following.
Output
B03
⎯
Coincidence output
1 (+)
• Operating load voltage: 4.75 to 30VDC
• Maximum load current: 0.1A/point
• Maximum voltage drop at ON: 0.5V
• Response time
OFF
→
ON: 1µs or less
(rated load, resistive load)
ON
→
OFF: 1µs or less
(rated load, resistive load)
⎯
A03
⎯
Coincidence output
2 (+)
B01
⎯
Coincidence output
3 (+)
A01
⎯
Coincidence output
4 (+)
B02,
A02
B02,
A02
Coincidence output
common (-)
Logic status
*1
External
wiring
ON/OFF status of CH
Function input terminal (FUNC1, FUNC2) in
terms of the high-speed counter module
Positive logic
No voltage
applied
OFF
Voltage applied
ON
Negative logic
No voltage
applied
ON
Voltage applied
OFF
I/O
clas-
sifica-
tion
Internal circuit
Pin
number
Signal name
Operation
Input
voltage
(guaranteed
value)
Operating
current
(guaranteed
value)
Response
time
CH1
CH2
680
680
680
680
4.7k
4.7k
4.7k
4.7k
EQUCOM
EQU4
EQU3
EQU2
EQU1
IO 5V