172
8.20
Function at the Extension Module Installation
One extension I/O module can be connected to one high-speed counter module.
In addition, functions unique to the extension I/O module can be used.
●
Turn off the high-speed counter module before replacing the extension I/O module. If the extension module is removed
when the module power supply is on, the error code (1F00
H
) is stored to CH1 Latest error code (RWr22), Error status flag
(RXA) turns on, and the ERR. LED turns on. The main module stops its operation.
●
After replacing the extension I/O module, write the parameters again.
(1) Functions available with an extension I/O module connected
*1
The function cannot be used with the cam switch function.
Function
Reference
Cam switch function
External power supply monitoring function
Output HOLD/CLEAR setting function
Cyclic data update watch function
Input response time setting function
Number of ON times integration function
*1
CC-Link IE Field Network Remote I/O Module User's Manual
Содержание NZ2GFCF-D62PD2
Страница 1: ......
Страница 2: ......
Страница 54: ...52 Memo ...
Страница 206: ...204 Memo ...
Страница 303: ......
Страница 304: ......