247
APPENDICES
A
Appendix 1 Details of R
emote I/O Signa
ls
Appendix 1.1 Details of r
emote input sig
nals
RX33
CH1
Measured pulse
value update
flag reset
completed
(Latch counter
input terminal)
• This signal turns on when resetting CH
Measured pulse value update flag (Latch counter
input terminal) (RX34, RX4C) by CH
Measured pulse value update flag reset command
(Latch counter input terminal) (RY33, RY4B) is completed.
• This signal turns off when CH
Measured pulse value update flag reset command (Latch
counter input terminal) (RY33, RY4B) is turned off.
RX4B
CH2
RX34
CH1
Measured pulse
value update
flag (Latch
counter input
terminal)
• This signal turns on when CH
Measured pulse value (Latch counter input terminal)
(RWr1E to RWr1F, RWr36 to RWr37) is updated.
• CH
Measured pulse value (Latch counter input terminal) (RWr1E to RWr1F, RWr36 to
RWr37) is updated without resetting this flag.
• This signal turns off when CH
Measured pulse value update flag reset command (Latch
counter input terminal) (RY33, RY4B) is turned on.
• Up to
Δ
T
1
*1
delay occurs until this signal turns on after CH
Measured pulse value (Latch
counter input terminal) (RWr1E to RWr1F, RWr36 to RWr37) is updated.
(For the overview of the operation, refer to the description of CH
Measured pulse value
update flag reset completed (Latch counter input terminal) (RX33, RX4B).)
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RX4C
CH2
RX35
CH1
ON width setting
change
completed
(PWM output)
• This signal turns on when the changes of CH
ON width setting (PWM output) (RWw1E to
RWw1F, RWw36 to RWw37) are reflected to the high-speed counter module by CH
ON
width setting change request (PWM output) (RY35, RY4D).
• This signal turns off when CH
ON width setting change request (PWM output) (RY35,
RY4D) is turned off.
RX4D
CH2
Remote input
(RX) No.
Signal name
Description
CH Measured pulse value
update flag reset command
(Latch counter input terminal) (RY33, RY4B)
CH Measured pulse value update flag
(Latch counter input terminal)
(RX34, RX4C)
CH Measured pulse value
update flag reset completed
(Latch counter input terminal) (RX33, RX4B)
Controlled by the high-speed counter module
Controlled by the program
ON
OFF
ON
OFF
ON
OFF
100
200
CH ON width setting change request
(PWM output)
(RY35, RY4D)
CH ON width setting
(PWM output)
(RWw1E to RWw1F, RWw36 to RWw37)
CH ON width setting change completed
(PWM output)
(RX35, RX4D)
Controlled by the high-speed counter module
Controlled by the program
ON
OFF
ON
OFF