135
CHAPTER 8 FUNCTIONS
8
8.8 La
tch C
ounter F
unction
(Counte
r Fu
nction Selection)
●
When the latch counter function is performed by CH
Function input terminal (FUNC1, FUNC2), the operation response
time follows CH
Function input response time setting (address: 0129
H
.b2 to b3, 0149
H
.b2 to b3)). Since CH
Latch
count value (RWr12 to RWr13, RWr2A to RWr2B) is updated synchronizing with the internal control cycle, a maximum of
delay time shown below occurs until the acquired value is stored.
•
Δ
T
1
*1
+ Setting time of CH
Function input response time setting (address: 0129
H
.b2 to b3, 0149
H
.b2 to b3)
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
●
The latch counter function cannot be performed while CH
Selected counter function start command (RY25, RY3D) or
CH
Function input terminal (FUNC1, FUNC2) is on even if the other is turned on.
Содержание NZ2GFCF-D62PD2
Страница 1: ......
Страница 2: ......
Страница 54: ...52 Memo ...
Страница 206: ...204 Memo ...
Страница 303: ......
Страница 304: ......