216
601
H
Moderate error
CH
Moving
average count
setting error
(Frequency
measurement)
A value other than 1 to
100 is set in CH
Moving
average count (Frequency
measurement) (RWw19,
RWw31).
indicates the channel
where settings are
incorrect.
*9 *3
Set CH
Moving average
count (Frequency
measurement) (RWw19,
RWw31) to a value between 1
and 100, and turn off then on
CH
Count enable command
(RY24, RY3C).
602
H
Moderate error
CH
Time unit
setting error
(Frequency
measurement)
A value other than 0 to 2 is
set in CH
Time unit
setting (Frequency
measurement) (RWw18,
RWw30).
indicates the channel
where settings are
incorrect.
*9 *3
Set CH
Time unit setting
(Frequency measurement)
(RWw18, RWw30) to a value
between 0 and 2, and turn off
then on CH
Count enable
command (RY24, RY3C).
621
H
Moderate error
CH
Moving
average count
setting error
(Rotation speed
measurement)
A value other than 1 to
100 is set in CH
Moving
average count (Rotation
speed measurement)
(RWw19, RWw31).
indicates the channel
where settings are
incorrect.
*10 *3
Set CH
Moving average
count (Rotation speed
measurement) (RWw19,
RWw31) to a value between 1
and 100, and turn off then on
CH
Count enable command
(RY24, RY3C).
622
H
Moderate error
CH
Time unit
setting error
(Rotation speed
measurement)
A value other than 0 to 2 is
set in CH
Time unit
setting (Rotation speed
measurement) (RWw18,
RWw30).
indicates the channel
where settings are
incorrect.
*10 *3
Set CH
Time unit setting
(Rotation speed measurement)
(RWw18, RWw30) to a value
between 0 and 2, and turn off
then on CH
Count enable
command (RY24, RY3C).
623
H
Moderate error
CH
Number
of pulses per
rotation setting
error
A value other than 1 to
8000000 is set in CH
Number of pulses per
rotation (RWw1A to
RWw1B, RWw32 to
RWw33).
indicates the channel
where settings are
incorrect.
*10 *3
Set CH
Number of pulses per
rotation (RWw1A to RWw1B,
RWw32 to RWw33) to a value
between 1 and 8000000, and
turn off then on CH
Count
enable command (RY24,
RY3C).
660
H
Moderate error
CH
Pulse
measurement
range overflow
error (Function
input terminal)
A pulse from CH
Function input terminal
(FUNC1 or FUNC2) is
beyond the measurable
range (approx. 214s).
indicates the channel
where settings are
incorrect.
*11 *3
Measure pulses within the
measurable range.
To resume the measurement,
take either of the following
actions.
• Input the target pulses again.
• Turn off then on CH
Pulse
measurement start command
(Function input terminal)
(RY30, RY48).
661
H
Moderate error
CH
Pulse
measurement
setting error
(Function input
terminal)
A value other than 0 and 1
is set in CH
Pulse
measurement setting
(Function input terminal)
(address: 012A
H
, 014A
H
).
indicates the channel
where settings are
incorrect.
*13
Set CH
Pulse measurement
setting (Function input terminal)
(address: 012A
H
, 014A
H
) to 0
or 1, and turn off then on Initial
data setting request flag (RY9).
Error code
(hexadecimal)
Classification
Error name
Description and
cause
Operation of when an error
occurs
Action
Error CH
The other
CHs