246
RX2D
Update flag
(Measured
frequency
value)
• This signal turns on when CH
Measured frequency value (RWr1A to RWr1B, RWr32 to
RWr33) is updated. (
• CH
Measured frequency value (RWr1A to RWr1B, RWr32 to RWr33) is updated without
resetting this flag.
• This signal turns off when CH
Update flag reset command (Measured frequency value)
(RY2C, RY44) is turned on.
• Up to
Δ
T
1
*1
delay occurs until this signal turns on after CH
Measured frequency value
(RWr1A to RWr1B, RWr32 to RWr33) is updated.
(For the overview of the operation, refer to the description of CH
Update flag reset
completed (Measured frequency value) (RX2C, RX44).)
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
CH1
Update flag
(Measured
rotation speed
value)
• This signal turns on when CH
Measured rotation speed value (RWr1A to RWr1B, RWr32
to RWr33) is updated. (
• CH
Measured rotation speed value (RWr1A to RWr1B, RWr32 to RWr33) is updated
without resetting this flag.
• This signal turns off when CH
Update flag reset command (Measured rotation speed
value) (RY2C, RY44) is turned on.
• Up to
Δ
T
1
*1
delay occurs until this signal turns on after CH
Measured rotation speed value
(RWr1A to RWr1B, RWr32 to RWr33) is updated.
(For the overview of the operation, refer to the description of CH
Update flag reset
completed (Measured rotation speed value) (RX2C, RX44).)
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RX45
CH2
RX31
CH1
Measured pulse
value update
flag reset
completed
(Function input
terminal)
• This signal turns on when resetting CH
Measured pulse value update flag (Function input
terminal) (RX32, RX4A) by CH
Measured pulse value update flag reset command
(Function input terminal) (RY31, RY49) is completed.
• This signal turns off when CH
Measured pulse value update flag reset command (Function
input terminal) (RY31, RY49) is turned off.
RX49
CH2
RX32
CH1
Measured pulse
value update
flag (Function
input terminal)
• This signal turns on when CH
Measured pulse value (Function input terminal) (RWr1C to
RWr1D, RWr34 to RWr35) is updated.
• CH
Measured pulse value (Function input terminal) (RWr1C to RWr1D, RWr34 to RWr35)
is updated without resetting this flag.
• This signal turns off when CH
Measured pulse value update flag reset command (Function
input terminal) (RY31, RY49) is turned on.
• Up to
Δ
T
1
*1
delay occurs until this signal turns on after CH
Measured pulse value
(Function input terminal) (RWr1C to RWr1D, RWr34 to RWr35) is updated.
(For the overview of the operation, refer to the description of CH
Measured pulse value
update flag reset completed (Function input terminal) (RX31, RX49).)
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RX4A
CH2
Remote input
(RX) No.
Signal name
Description
CH Measured pulse value
update flag reset command
(Function input terminal) (RY31, RY49)
CH Measured pulse value update flag
(Function input terminal) (RX32, RX4A)
CH Measured pulse value
update flag reset completed
(Function input terminal) (RX31, RX49)
Controlled by the high-speed counter module
Controlled by the program
ON
OFF
ON
OFF
ON
OFF
Содержание NZ2GFCF-D62PD2
Страница 1: ......
Страница 2: ......
Страница 54: ...52 Memo ...
Страница 206: ...204 Memo ...
Страница 303: ......
Страница 304: ......