1 - 25
1. FUNCTIONS AND CONFIGURATION
(4) MR-J3-200B4
R S T
L
21
L
11
C
P
(Note 3)
Power supply
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
(Note 2)
Line noise filter
(FR-BSF01)
(Note 2)
Power factor
improving DC
reactor
(FR-BEL-H)
L
1
L
2
L
3
P
1
Regenerative
option
Servo amplifier
CN5
CN3
CN1A
CN1B
CN2
CN4
(Note 1)
Battery
MR-J3BAT
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
MR Configurator
Servo motor
U V
W
Personal
computer
P
2
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1
-P
2
.
3. Refer to section 1.3 for the power supply specification.