7 - 10
7. SPECIAL ADJUSTMENT FUNCTIONS
7.5 Low-pass filter
(1) Function
When a ballscrew or the like is used, resonance of high frequency may occur as the response level of the
servo system is increased. To prevent this, the low-pass filter is factory-set to be valid for a torque
command. The filter frequency of this low-pass filter is automatically adjusted to the value in the following
expression:
Filter frequency(rad/s)
1 + GD2
VG2
10
When parameter No. PB23 is set to " 1 ", manual setting can be made with parameter No. PB18.
(2) Parameter
Set the operation of the low-pass filter selection (parameter No. PB23.)
Parameter No. PB23
Low-pass filter selection
0: Automatic setting (initial value)
1: Manual setting (parameter No. PB18 setting)
7.6 Gain changing function
This function can change the gains. You can change between gains during rotation and gains during stop or
can use an external signal to change gains during operation.
7.6.1 Applications
This function is used when:
(1) You want to increase the gains during servo lock but decrease the gains to reduce noise during rotation.
(2) You want to increase the gains during settling to shorten the stop settling time.
(3) You want to change the gains using an external signal to ensure stability of the servo system since the load
inertia moment ratio varies greatly during a stop (e.g. a large load is mounted on a carrier).
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...