13. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
Note 1. For power supply specifications, refer to section 13.1.3.
2. Configure the circuit to turn OFF the forced stop (EM1) of the drive unit and the converter unit at the same time.
3. Always connect between P
1
and P
2
terminals (Factory-wired). When using the power factor improving DC reactor, refer to
section 13.9.6.
4. Connect P/ and N/ terminals of the brake unit to a correct destination. Wrong connection results in the converter unit and
brake unit malfunction.
5. For the converter unit and the drive unit of 400V class, a stepdown transformer is required.
6. Contact rating: 1b contact, 110VAC_5A/220VAC_3A
Normal condition: TH1-TH2 is conducting. Abnormal condition: TH1-TH2 is not conducting.
7. Contact rating: 230VAC_0.3A/30VDC_0.3A
Normal condition: B-C is conducting/A-C is not conducting. Abnormal condition: B-C is not conducting/A-C is conducting.
8. Connect the thermal relay censor of the servo motor.
9. Do not connect more than one cable to each L and L terminals of TE2-1 of the converter unit.
10. Always connect between BUE and SD terminals (Factory-wired).
11. Connect MSG and SD terminals of the brake unit to a correct destination. Wrong connection results in the converter unit and
brake unit malfunction.
12. For connecting L and L - terminals of TE2-1 of the converter unit to the terminal block, use the cable indicated in (3) (d) of
this section.
(c) Precautions for wiring
The cables between the converter unit and the brake unit, and between the resistor unit and the brake
unit should be as short as possible. Always twist the cable longer than 5m (twist five times or more per
one meter). Even when the cable is twisted, the cable should be less than 10m. Using cables longer
than 5m without twisting or twisted cables longer than 10m, may result in the brake unit malfunction.
Converter unit
Brake unit
5m or less
5m or less
Converter unit
Brake unit
10m or less
10m or less
P
N
P
N
P
PR
PR
P
N
P
PR
P
PR
Twist
Resistor unit
Resistor unit
P
N
Twist
P
(d) Cables
1) Cables for the brake unit
For the brake unit, HIV cable (600V grade heat-resistant PVC insulated wire) is recommended.
a) Main circuit terminal
Cable size
Crimping
terminal
N/ , P/ , PR,
Brake unit
Main
circuit
terminal
screw
size
N/ , P/ ,
PR,
Tightening
torque
[N m]
HIV cables,
etc. [mm
2
]
AWG
200V
class
FR-BU2-55K M6 14-6 4.4
14
6
400V
FR-BU2-H55K
M5 5.5-5 2.5 5.5
10
N/
P/
PR
Terminal block
class FR-BU2-H75K
M6
14-6
4.4
14
6
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...