11 - 11
11. OPTIONS AND AUXILIARY EQUIPMENT
(b) Internal wiring diagram
MR-EKCBL20M-L
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
3
7
9
SD
Plate
1
2
8
9
P5G
MR
MRR
SHD
P5E
BAT
BAT
(Note)
MR-EKCBL30M-L
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
MDR
8
5
3
7
4
MD
7
9
SD
1
2
8
9
P5G
MR
MRR
MDR
MD
SHD
P5E
6
CONT
BAT
BAT
Plate
(Note)
MR-EKCBL20M-H
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
3
7
9
SD
1
2
8
9
P5G
MR
MRR
SHD
P5E
BAT
BAT
(Note)
Plate
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
MDR
8
5
3
7
4
MD
7
9
SD
1
2
8
9
P5G
MR
MRR
MDR
MD
SHD
P5E
6
CONT
BAT
BAT
(Note)
Plate
Note. Always make connection for use in an absolute position detection system. Wiring is not necessary for use in an incremental
system.
When fabricating the cable, use the wiring diagram corresponding to the length indicated below.
Applicable Wiring Diagram
Cable Flex Life
Less than 10m
30m to 50m
Standard MR-EKCBL20M-L
Long flex
MR-EKCBL20M-H
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...