11 - 24
11. OPTIONS AND AUXILIARY EQUIPMENT
The following are setting values for regenerative resistor and regenerative brake option which are used with
a servo amplifier of 11k to 22kW.
Regenerative resistor, regenerative brake option
Setting
value
Standard supplied regenerative resistor
00
Standard supplied regenerative resistor
(with a cooling fan to cool it)
FA
MR-RB5E 00
MR-RB5E (with a cooling fan to cool it)
FA
MR-RB9P 00
MR-RB9P (with a cooling fan to cool it)
FA
MR-RB9F 00
MR-RB9F (with a cooling fan to cool it)
FA
MR-RB6B-4 00
MR-RB6B-4 (with a cooling fan to cool it)
00
MR-RB60-4 FA
MR-RB60-4 (with a cooling fan to cool it)
00
MR-RB6K-4 FA
MR-RB6K-4 (with a cooling fan to cool it)
00
(4) Connection of the regenerative option
POINT
When the MR-RB50 MR-RB51 MR-RB3M-4 MR-RB3G-4 MR-RB5G-4
MR-RB34-4 MR-RB54-4 is used, a cooling fan is required to cool it.
The cooling fan should be prepared by the customer.
For the sizes of wires used for wiring, refer to section 11.11.
The regenerative option will generate heat of about 100 . Fully examine heat dissipation, installation
position, used cables, etc. before installing the option. For wiring, use flame-resistant cables and keep them
clear of the regenerative option body. Always use twisted cables of max. 5m length for connection with the
servo amplifier.
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...