6 - 12
6. GENERAL GAIN ADJUSTMENT
6.5 Differences between MELSERVO-J2-Super and MELSERVO-J3 in auto tuning
To meet higher response demands, the MELSERVO-J3 series has been changed in response level setting
range from the MELSERVO-J2S-Super series. The following table lists comparison of the response level
setting.
MELSERVO-J2-Super MELSERVO-J3
Parameter No. 9 Setting
Guideline for Machine Resonance
Frequency [Hz]
Parameter No. PA09 Setting
Guideline for Machine Resonance
Frequency [Hz]
1 10.0
2 11.3
3 12.7
1 15 4 14.3
5 16.1
6 18.1
2 20 7 20.4
8
23.0
3 25 9 25.9
4 30 10
29.2
11
32.9
5 35 12
37.0
13
41.7
6 45 14
47.0
7 55 15
52.9
16
59.6
8 70 17
67.1
18
75.6
9 85 19
85.2
20
95.9
A 105 21
108.0
22
121.7
B 130 23
137.1
C 160 24
154.4
25
173.9
D 200 26
195.9
27
220.6
E 240 28
248.5
29
279.9
F 300 30
315.3
31 355.1
32 400.0
Note that because of a slight difference in gain adjustment pattern, response may not be the same if the
resonance frequency is set to the same value.
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...