5 - 13
5. PARAMETERS
No. Symbol
Name
and
Function
Initial
Value
Unit
Setting
Range
PB14 NHQ1 Notch shape selection 1
Used to selection the machine resonance suppression filter 1.
Notch depth selection
Setting value
Depth
Gain
0
Deep
1
14dB
2
8dB
3
4dB
Shallow
Notch width
Setting value
Width
0
2
Standard
1
3
2
4
3
5
Wide
0
0
to
to
40dB
Setting parameter No. PB01 (filter tuning mode 1) to " 1" automatically changes
this parameter.
When the parameter No. PB01 setting is " 0", the setting of this parameter is
ignored.
0000h Refer
to
Name
and
function
column.
PB15 NH2 Machine resonance suppression filter 2
Set the notch frequency of the machine resonance suppression filter 2.
Set parameter No. PB16 (notch shape selection 2) to " 1" to make this parameter
valid.
4500 Hz 100
to
4500
PB16 NHQ2 Notch shape selection 2
Select the shape of the machine resonance suppression filter 2.
Notch depth selection
Setting value Depth
Gain
0
40dB
Deep
1
14dB
2
8dB
3
4dB
Shallow
to
Notch width
Setting value
Width
0
2
Standard
1
3
2
4
3
5
Wide
to
0
Machine resonance suppression filter 2 selection
0: Invalid
1: Valid
0000h Refer
to
Name
and
function
column.
PB17 Automatic
setting
parameter
The value of this parameter is set according to a set value of parameter No.PB06 (Ratio
of load inertia moment to servo motor inertia moment).
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...