background image

INSTRUCTION MANUAL

iPA5060
iPA5120

Ethernet Power Amplifier Terminal

Thank you 

for choosing another quality product from Amperes Electronics.

Introducing the new arrival : iPA5060 - 60W 100V line and iPA5120 - 120W 100V line Ethernet Amplifier Terminals which has 

expanded the IP range of products further. Both are suitable for decentralised IP PA system in locations such as park kiosks, 

ticketing booths, classrooms, floor risers, pole mounted speakers for power plants, ports etc.

It has local audio source input, which can be either Mic or Line level, to enable local paging such as in classroom or park 

entrance. The local source shall be overrided by central paging and the highest priority shall be accorded to Emergency Paging 

or EVAC messages, to comply with EN54 or BS5839 requirement. Configuring the amplifier terminal is simple with user friendly 

brower interface, thanks to our detailed study and feedback from installers.

Version 1/19

N

O

I

T

A

L

I

T

N

E

V

 

E

T

A

U

Q

E

D

A

S

E

R

I

U

Q

E

R

 

T

N

E

M

P

I

U

Q

E

 

S

I

H

T

T

N

E

V

 

K

C

O

L

B

 

T

O

N

 

O

D

R

O

 

E

R

I

F

 

F

O

 

K

S

I

R

 

E

H

T

 

E

C

U

D

E

R

 

O

T

S

I

H

T

 

E

S

O

P

X

E

 

T

O

N

 

O

D

 

K

C

O

H

S

 

C

I

R

T

C

E

L

E

.

E

R

U

T

S

I

O

M

 

R

O

 

N

I

A

R

 

O

T

 

T

N

E

M

P

I

U

Q

E

G

N

I

N

R

A

W

MADE IN MALAYSIA

Another Quality Product From

AMPERES ELECTRONICS

ETHERNET POWER AMPLIFIER

IPA 5120

amperes

R

IP AMPLIFIER TERMINAL

WITH LOCAL SOURCE IN

120W 100V LINE

R

O

 

E

S

U

 

R

O

O

D

N

R

O

F

 

E

L

B

A

T

I

U

S

R

E

P

O

R

P

 

H

T

I

W

 

E

R

U

S

O

L

C

N

E

N

O

I

T

A

L

I

T

N

E

V

70V(41Ω)

COM

22V(4Ω)

COM

100V(83Ω)

MIC

IN - 

IN +   

GND

IN -    

IN + 

LINE

OUT

+

GND

OUT

-

LINK

SPEAKER OUTPUT

AUDIO INPUT / LINK TERMINALS

AC 220 - 240V 50/60Hz 1.3A

POWER

O

I

RESET

ETHERNET

MIC

LINE

SELECTION

INPUT LEVEL

INPUT

OUTPUT

VOLUME CONTROL

MIN

MAX

MIN

MAX

LOCAL BGM / MIC

SERVER

POWER

STREAMING

LOCAL BGM / MIC

Содержание iPA5060

Страница 1: ...guring the amplifier terminal is simple with user friendly brower interface thanks to our detailed study and feedback from installers Version 1 19 N O I T A L I T N E V E T A U Q E D A S E R I U Q E R T N E M P I U Q E S I H T T N E V K C O L B T O N O D R O E R I F F O K S I R E H T E C U D E R O T S I H T E S O P X E T O N O D K C O H S C I R T C E L E E R U T S I O M R O N I A R O T T N E M P I...

Страница 2: ...ier for extra power amplification Front View Rear View AC 220 240V 50 60Hz 1 3A 70V 41Ω COM 22V 4Ω COM 100V 83Ω MIC IN IN GND IN IN LINE OUT GND OUT LINK MIC LINE RESET ETHERNET SPEAKER OUTPUT AUDIO INPUT LINK TERMINALS SELECTION INPUT LEVEL O I INPUT OUTPUT VOLUME CONTROL POWER 4 10 11 12 5 7 8 9 6 N O I T A L I T N E V E T A U Q E D A S E R I U Q E R T N E M P I U Q E S I H T T N E V K C O L B T...

Страница 3: ... MADE IN MALAYSIA Another Quality Product From AMPERES ELECTRONICS ETHERNET POWER AMPLIFIER IPA 5120 amperes R IP AMPLIFIER TERMINAL WITH LOCAL SOURCE IN 120W 100V LINE ADEQUATE VENTILATION THIS EQUIPMENT REQUIRES DO NOT BLOCK VENT SUITABLE FOR INDOOR USE OR ENCLOSURE WITH PROPER VENTILATION LOCAL BGM MIC STREAMING POWER STATUS SERVER AC 220 240V 50 60Hz 1 3A RESET ETHERNET MIC LINE SELECTION INPU...

Страница 4: ...e input Line input Balanced input Network switch cat5e 220 240V ac Link to Amplifier for additional speaker installation Device Setup Via Browser Info Main Page Info Providing hardware network and paging server information This shall be the first page once you entered the system s http browser Network Information For configuration of IP address and its related ports Paging Server For Paging Server...

Страница 5: ... of the iPA5060 5120 of which the client is connected to Zone Range Zones that is served by the client unit Restricted zones Zones that only allows high priority paging siren Web Page Theme You can choose the theme of the web page Audio You can setting the configuration target volume and graphic equalizer Authentication You can alter the user name and password to avoid unnecessary access to the sy...

Страница 6: ...Server Reset Bootloading If the client hanged it is required to perform system reset by When it is required to update the units firmware for bugs fixing or features upgrade you can manage it by using browser at its designated IP address default at 192 168 0 100 Update via Browser 1 2 3 To update follow the steps below Download the updated firmware from our website or source it directly from our se...

Страница 7: ...otocols Digital format decode User interface Local control Firmware upgrade Priority controls low to high Case Dimension WxHxD Weight 220 240V ac 50 60 Hz 1 mic or line level balanced signal via 8 way connector Mic 600 Ohm Line 10K Ohm 40 to 4 dBu 60 120W 22V 70Hz 15KHz 1KHz 3 dB 70 dB 1 KHz 1V 0 18 Thermal short circuit overload fuse Inrush current 75 Deg C Auto temperature controlled fan speed R...

Страница 8: ...formed by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the product from the main system are for the account of the purchaser This warranty shall not extend to the replacement of the unit This warranty does not cover damages caused by misuse neglect accident of t...

Отзывы: