11 - 46
11. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
NFB
MC
Servo amplifier
L
11
L
21
L
1
L
2
L
3
SK
ON
MC
B C
N
P
C
RDY
SE
Alarm
output
RDY
output
A
B
C
5m or less
Operation ready
MC
OFF
EMG
ALM
RA2
FR-RC-(H)
Ready
Power factor improving reactor
FR-BAL-(H)
R/L
1
S/L
2
T/L
3
B
C
R
RX
R
SX
S
TX
T
Phase detection
terminals
(Note 1)
Power regeneration
converter FR-RC-(H)
N/
P/
EM1
RA
DOCOM
DICOM
ALM
Trouble(Note 3)
DOCOM
Forced stop
24VDC
P
2
P
1
(Note 4)
(Note 2)
CN3
CN3
(Note 5)
(Note 6)
Power supply
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain
removed, the FR-RC-(H) will not operate.
2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected
to P terminal and C terminal.
3. When setting not to output Trouble (ALM) with parameter change, configure power supply circuit for turning
magnetic contactor off after detecting an occurrence of alarm on the controller side.
4. Always connect P
1
-P
2
(For 11k to 22kW, connect P
1
-P). (Factory-wired.) When using the power factor improving
DC reactor, refer to section 11.13.
5. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class in 400V class servo
amplifiers.
6. Refer to section 1.3 for the power supply specification.
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...