6 - 11
6. GENERAL GAIN ADJUSTMENT
6.4 Interpolation mode
The interpolation mode is used to match the position loop gains of the axes when performing the interpolation
operation of servo motors of two or more axes for an X-Y table or the like. In this mode, the model loop gain
and speed loop gain which determine command track ability are set manually and the other parameter for gain
adjustment are set automatically.
(1) Parameter
(a) Automatically adjusted parameters
The following parameters are automatically adjusted by auto tuning.
Parameter No.
Abbreviation
Name
PB06
GD2
Ratio of load inertia moment to servo motor inertia moment
PB08 PG2
Position
loop
gain
PB09 VG2
Speed
loop
gain
PB10 VIC
Speed
integral
compensation
(b) Manually adjusted parameters
The following parameters are adjustable manually.
Parameter No.
Abbreviation
Name
PB07 PG1
Model
loop
gain
(2) Adjustment procedure
Step Operation
Description
1
Set to the auto tuning mode.
Select the auto tuning mode 1.
2
During operation, increase the response level setting (parameter No.
PA09), and return the setting if vibration occurs.
Adjustment in auto tuning mode 1.
3
Check the values of model loop gain.
Check the upper setting limits.
4
Set the interpolation mode (parameter No. PA08: 0000).
Select the interpolation mode.
5
Set the model loop gain of all the axes to be interpolated to the same
value. At that time, adjust to the setting value of the axis, which has the
smallest model loop gain.
Set position loop gain.
6
Looking at the interpolation characteristic and rotation status, fine-adjust
the gains and response level setting.
Fine adjustment.
(3) Adjustment description
(a) Model loop gain (parameter No. PB07)
This parameter determines the response level of the position control loop. Increasing model loop gain
improves track ability to a position command but a too high value will make overshooting liable to occur
at the time of settling. The droop pulse value is determined by the following expression.
60
Rotation speed (r/min)
Model loop gain setting
Droop pulse value (pulse)
262144(pulse)
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...