3 - 51
3. SIGNALS AND WIRING
3.13 Control axis selection
POINT
The control axis number set to rotary axis setting switch (SW1) should be the
same as the one set to the servo system controller.
Use the rotary axis setting switch (SW1) to set the control axis number for the servo. If the same numbers
are set to different control axes in a single communication system, the system will not operate properly. The
control axes may be set independently of the SSCNET cable connection sequence.
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
Rotary axis setting switch (SW1)
Down
Up
Test operation select switch (SW2-1)
Set the test operation select switch to the "Up" position, when
performing the test operation mode by using MR Configurator.
Spare (Be sure to set to the "Down" position.)
(Note) SW2
Note. This table indicates the status when the switch is set to "Down".
(Default)
Spare
Rotary axis setting switch (SW1)
Description
Display
0 Axis
No.1
01
1 Axis
No.2
02
2 Axis
No.3
03
3 Axis
No.4
04
4 Axis
No.5
05
5 Axis
No.6
06
6 Axis
No.7
07
7 Axis
No.8
08
8 Axis
No.9
09
9 Axis
No.10
10
A Axis
No.11
11
B Axis
No.12
12
C Axis
No.13
13
D Axis
No.14
14
E Axis
No.15
15
Down
(Be sure to set to the
"Down" position.)
F Axis
No.16
16
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...