5 - 6
5. PARAMETERS
(2) Auto tuning response (parameter No. PA09)
If the machine hunts or generates large gear sound, decrease the set value. To improve performance, e.g.
shorten the settling time, increase the set value.
Setting Response
Guideline for Machine
Resonance Frequency [Hz]
Setting
Response
Guideline for Machine
Resonance Frequency [Hz]
1
Low
response 10.0
17
Low
response 67.1
2 11.3
18 75.6
3 12.7
19 85.2
4 14.3
20 95.9
5 16.1
21 108.0
6 18.1
22 121.7
7 20.4
23 137.1
8 23.0
24 154.4
9 25.9
25 173.9
10 29.2
26 195.9
11 32.9
27 220.6
12 37.0
28 248.5
13 41.7
29 279.9
14 47.0
30 315.3
15
52.9
31
355.1
16
Middle response
59.6
32
Middle response
400.0
5.1.7 In-position range
Parameter
No. Symbol
Name
Initial Value
Unit
Setting Range
PA10
INP
In-position range
100
pulse
0 to 65535
POINT
This parameter cannot be used in the speed control mode.
Set the range, where ln position (INP) is output, in the command pulse unit.
Servo motor droop pulse
In-position range [pulse]
Command pulse
Command pulse
Droop pulse
In position (INP)
ON
OFF
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...