11.19 EMC filter (recommended)
For compliance with the EMC directive of the EN Standard, it is recommended to use the following filter: Some
EMC filters are large in leakage current.
(1) Combination with the servo amplifier
Recommended filter (Soshin Electric)
Servo amplifier
Model
Leakage current [mA]
Mass [kg]([lb])
MR-J3-10B to MR-J3-100B
MR-J3-10B1 to MR-J3-40B1
(Note) HF3010A-UN
3 (6.61)
MR-J3-250B MR-J3-350B (Note)
HF3030A-UN
5
5.5 (12.13)
MR-J3-500B MR-J3-700B
(Note) HF3040A-UN
1.5
6.0 (13.23)
MR-J3-11KB to MR-J3-22KB
(Note) HF3100A-UN
6.5
15 (33.07)
MR-J3-60B4 MR-J3-100B4 TF3005C-TX
MR-J3-200B4 to MR-J3-700B4
TF3020C-TX
6(13.23)
MR-J3-11KB4 TF3030C-TX
7.5(16.54)
MR-J3-15KB4 TF3040C-TX
MR-J3-22KB4 TF3060C-TX
5.5
12.5(27.56)
Note. A surge protector is separately required to use any of these EMC filters.
(2) Connection example
L
1
L
2
L
3
11
L
21
Servo amplifier
1
2
3
4
5
6
E
MC
(Note 2)
Surge protector 1
(RAV-781BYZ-2)
(OKAYA Electric Industries Co., Ltd.)
(Note 2)
Surge protector 2
(RAV-781BXZ-4)
(OKAYA Electric Industries Co., Ltd.)
NFB
(Note 1)
Power supply
1
2
3
1
2
3
EMC filter
Note 1. For 1-phase 200V to 230VAC power supply, connect the power supply to L
1
,L
2
and leave L
3
open.
There is no L
3
for 1-phase 100 to 120VAC power supply. Refer to section 1.3 for the power supply specification.
2. The example is when a surge protector is connected.
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...