5 - 20
5. PARAMETERS
No. Symbol
Name
and
Function
Initial
Value
Unit
Setting
Range
PC12
MO2
Analog monitor 2 offset
Used to set the offset voltage of the analog monitor2 (MO2) output.
0 mV
-999
to
999
PC13 MOSDL Analog monitor feedback position output standard data Low
Used to set the standard position of feedback output with analog monitor 1 (M01) or 2
(M02).
For this parameter, the lower-order four digits of standard position in decimal numbers
are set.
0 pulse
-9999
to
9999
PC14 MOSDH Analog monitor feedback position output standard data High
Used to set the standard position of feedback output with analog monitor 1 (M01) or 2
(M02).
For this parameter, the higher-order four digits of standard position in decimal numbers
are set.
0 10000
pulse
-9999
to
9999
PC15
0
PC16
For manufacturer setting
Do not change this value by any means.
0000h
PC17 **COP4 Function Selection C-4
Home position setting condition in the absolute position detection system can be
selected.
Selection of home position setting condition
0: Need to pass motor Z phase after the power
supply is switched on.
1: Not need to pass motor Z phase after the power
supply is switched on.
0 0 0
0000h Refer
to
Name
and
function
column.
PC18
0000h
PC19
0000h
PC20
For manufacturer setting
Do not change this value by any means.
0000h
PC21 *BPS
Alarm history clear
Used to clear the alarm history.
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the alarm
history is cleared at next power-on.
After the alarm history is cleared, the setting is
automatically made invalid (reset to 0).
0 0 0
0000h Refer
to
Name
and
function
column.
PC22
0000h
PC23
For manufacturer setting
Do not change this value by any means.
0000h
PC24
0000h
PC25
0000h
PC26
0000h
PC27
0000h
PC28
0000h
PC29
0000h
PC30
0000h
PC31
0000h
PC32
0000h
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...