11 - 35
11. OPTIONS AND AUXILIARY EQUIPMENT
11.3.1 Selection
Use a combination of servo amplifier, brake unit and resistor unit listed below.
Brake unit
Resistor unit
Number of
connected
units
Permissible
continuous
power [kW]
Total
resistance
[ ]
Applicable servo
amplifier
200V FR-BU2-15K
FR-BR-15K
1
0.99
8
MR-J3-500B (Note)
class
2
(parallel)
1.98
4
MR-J3-500B
MR-J3-700B
MR-J3-11KB
MR-J3-15KB
FR-BU2-30K
FR-BR-30K
1
1.99
4
MR-J3-500B
MR-J3-700B
MR-J3-11KB
MR-J3-15KB
FR-BU2-55K
FR-BR-55K
1
3.91
2
MR-J3-11KB
MR-J3-15KB
MR-J3-22KB
MT-BR5-55K
1
5.5
2
MR-J3-22KB
400V
class
FR-BU2-H30K FR-BR-H30K
1
1.99
16 MR-J3-500B4
MR-J3-700B4
MR-J3-11KB4
FR-BU2-H55K FR-BR-H55K
1
3.91
8
MR-J3-11KB4
MR-J3-15KB4
MR-J3-22KB4
FR-BU2-H75K MT-BR5-H75K
1
7.5
6.5 MR-J3-22KB4
11.3.2 Brake unit parameter setting
Normally, when using the FR-BU2-(H), changing parameters is not necessary. Whether a parameter can be
changed or not is listed below.
Parameter
No. Name
Change
possible/
impossible
Remarks
0
Brake mode switchover
Impossible
Do not change the parameter.
1
Monitor display data selection
Possible
Refer to the FR-BU2-(H) Brake Unit
Instruction Manual.
2
Input terminal function selection 1
3
Input terminal function selection 2
77 Parameter
write
selection
78 Cumulative
energization
time
carrying-over times
CLr Parameter
clear
ECL Alarm history clear
C1
For manufacturer setting
Impossible
Do not change the parameter.
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...