13 - 92
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
(b) Combination with MT-BR5-(H) resistor unit
1) When connecting a brake unit to a converter unit
NFB
Drive unit
Converter unit
L
1
L
2
L
3
L
11
L
21
(Note 1)
Power supply
L
L
L
L
1
MC1
2
MC2
CNP1
L
11
L
21
RA1
MC
SK
(Note 5)
RA2
RA3
Drive
unit
Converter
unit
Controller
forced stop
(Note 2)
Forced stop
EM1
Operation
ready
OFF/ON
RA4
Servo motor
thermal relay
(Note 8)
RA5
EM1
3
20
SD
Plate
DICOM
10
DOCOM
5
DICOM
ALM
15
CN3
RA1
Forced stop
(Note 2)
MC
CN1
1
DICOM
5
DOCOM
6
DICOM
2
ALM
7
EM1
9
DOCOM
(Note 2)
RA2
N/
P/
BUE
SD
PR
B
C
A
SD
MSG
(Note 4)
(Note 7)
RA5
FR-BU2-(H)
MT-BR5-(H)
P
PR
TH2
TH1
(Note 6)
SK
(Note 10)
P
1
P
2
L
L
(Note 9)
(Note 3)
24VDC
24VDC
Note 1. For power supply specifications, refer to section 13.1.3.
2. Configure the circuit to turn OFF the forced stop (EM1) of the drive unit and the converter unit at the same time.
3. Always connect between P
1
and P
2
terminals (Factory-wired). When using the power factor improving DC reactor, refer to
section 13.9.6.
4. Connect P/ and N/ terminals of the brake unit to a correct destination. Wrong connection results in the converter unit and
brake unit malfunction.
5. For the converter unit and the drive unit of 400V class, a stepdown transformer is required.
6. Contact rating: 1b contact, 110VAC_5A/220VAC_3A
Normal condition: TH1-TH2 is not conducting. Abnormal condition: TH1-TH2 is conducting.
7. Contact rating: 230VAC_0.3A/30VDC_0.3A
Normal condition: B-C is conducting/A-C is not conducting. Abnormal condition: B-C is not conducting/A-C is conducting.
8. Connect the thermal relay censor of the servo motor.
9. Do not connect more than one cable to each L and L terminals of TE2-1 of the converter unit.
10. Always connect between BUE and SD terminals (Factory-wired).
Содержание Melservo MR-J3- 350B4
Страница 15: ...A 14 MEMO ...
Страница 21: ...6 MEMO ...
Страница 107: ...3 52 3 SIGNALS AND WIRING MEMO ...
Страница 171: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 181: ...8 10 8 TROUBLESHOOTING MEMO ...
Страница 193: ...9 12 9 OUTLINE DRAWINGS MEMO ...
Страница 295: ...12 4 12 ABSOLUTE POSITION DETECTION SYSTEM 2 For MR J3 500B or more MR J3 350B4 or more Insert connector into CN4 ...
Страница 297: ...12 6 12 ABSOLUTE POSITION DETECTION SYSTEM MEMO ...
Страница 397: ...13 100 13 SERVO AMPLIFIERS WITH A LARGE CAPACITY 30k TO 55kW MEMO ...