40
(2) Positioning control
*1
When multiple positioning data is executed by the continuous positioning control and there is invalid setting value in a
positioning data, an error occurs and deceleration is performed at the previous positioning data. In this case, sudden
stop is not performed even when it is set for the stop group 3. If any of the following error occurs, the operation is
immediately stopped after executing up to previous positioning data of the positioning data where an error occurred.
• No command speed (error code: 503)
• Outside linear movement amount range (error code: 504)
• Large arc error deviation (error code: 506)
• Software stroke limit + (error code: 507)
• Software stroke limit - (error code: 508)
• Sub point setting error (error code: 525)
• End point setting error (error code: 526)
• Center point setting error (error code: 527)
• Outside radius range (error code: 544)
• Illegal setting of ABS direction in unit of degree (error code: 546)
*2
This means the stop using a stop button on the positioning test dialog box when using the positioning test function of GX
Works2.
Stop cause
Stop axis
M code ON
signal after stop
Axis operation
status ([Md.26])
after stopping
Stop process
Major positioning
control
High-level positioning
control
Forced stop
Drive unit READY signal
OFF
Each axis
No change
Error
Immediate stop
Fatal stop
(Stop group 1)
Hardware stroke limit
upper/lower limit error
occurrence
Each axis
No change
Error
Deceleration stop/sudden stop
(Select with "[Pr.37] Stop group 1 sudden stop
selection".)
Emergency stop
(Stop group 2)
CPU module error
occurrence
All axes
No change
Error
Deceleration stop/sudden stop
(Select with "[Pr.38] Stop group 2 sudden stop
selection".)
PLC READY signal OFF
Turns OFF
Error in test function
No change
Relatively safe stop
(Stop group 3)
Axis error detection
(Error other than stop
group 1 or 2)
Each axis
No change
Error
Deceleration stop/sudden stop
(Select with "[Pr.39] Stop group 3 sudden stop
selection".)
Intentional stop
(Stop group 3)
"Stop signal" ON from
external source
Each axis
No change
Stopped
(Standby)
"Axis stop signal" ON
from CPU module
"Stop signal" from GX
Works2
Содержание MELSEC-L LD75D
Страница 1: ...MELSEC L LD75P LD75D Positioning Module User s Manual LD75P1 LD75P2 LD75P4 LD75D1 LD75D2 LD75D4 ...
Страница 2: ......
Страница 11: ...9 Memo ...
Страница 47: ...45 CHAPTER 2 SYSTEM CONFIGURATION 2 2 1 General Image of System 1 When connected to a CPU module ...
Страница 176: ...174 ...
Страница 264: ...262 ...
Страница 266: ...264 ...
Страница 267: ...265 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 268: ...266 ...
Страница 269: ...267 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 270: ...268 ...
Страница 271: ...269 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 272: ...270 Z ABRST1 instruction execution ...
Страница 273: ...271 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 278: ...276 ...
Страница 279: ...277 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 280: ...278 ...
Страница 281: ...279 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 282: ...280 ...
Страница 283: ...281 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 284: ...282 ...
Страница 285: ...283 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 286: ...284 ...
Страница 287: ...285 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 316: ...314 Memo ...
Страница 685: ...683 APPENDICES A Appendix 1 Function Update Appendix 1 1 Function comparison Memo ...
Страница 738: ...736 Memo ...
Страница 806: ...804 5 LD75D2 Unit mm 6 LD75D4 Unit mm 45 4 90 4 95 4 45 45 DIN rail center 45 4 90 4 95 4 45 45 DIN rail center ...
Страница 817: ......