350
(d) Changing the speed (
The two modes for changing the speed are shown below.
• Standard switching
Switch the speed when executing the next positioning data.
• Front-loading switching
The speed switches at the end of the positioning data currently being executed.
[Standard speed switching mode]
• If the respective command speeds differ in the "positioning data currently being executed" and the
"positioning data to carry out the next operation", the machine will accelerate or decelerate after reaching
the positioning point set in the "positioning data currently being executed" and the speed will change over
to the speed set in the "positioning data to carry out the next operation".
• The parameters used in acceleration/deceleration to the command speed set in the "positioning data to
carry out the next operation" are those of the positioning data to carry out acceleration/deceleration. Speed
switching will not be carried out if the command speeds are the same.
• Speed switching condition
If the movement amount is small in regard to the target speed, the current speed may not reach the target
speed even if acceleration/deceleration is carried out. In this case, the machine is
accelerated/decelerated so that it nears the target speed.
If the movement amount will be exceeded when automatic deceleration is required (Ex. Operation
patterns "00", "01"), the machine will immediately stop at the designated positioning address, and a
warning "Insufficient movement distance" (warning code: 513) will occur.
When the speed cannot be changed over in P2
When the movement amount is small during automatic deceleration
When the relation of the speeds is P1 = P4, P2 = P3, P1 < P2.
The movement amount required to carry out the automatic deceleration cannot
be secured, so the machine immediately stops in a speed
0 status.
OFF
ON
OFF
ON
OFF
ON
OFF
ON
11
11
11
01
00
V
Dwell time
t
Speed
switching
Da. 1 O
peration pattern
Positioning
Start complete signal
BUSY signal
Positioning complete signal
Positioning start signal
[XC, XD, XE, XF]
[X10, X11, X12, X13]
[Y10, Y11, Y12, Y13]
Dwell time
[X14, X15, X16, X17]
P1
P2
P3
P4
Pn
Pn+1
Positioning address
Содержание MELSEC-L LD75D
Страница 1: ...MELSEC L LD75P LD75D Positioning Module User s Manual LD75P1 LD75P2 LD75P4 LD75D1 LD75D2 LD75D4 ...
Страница 2: ......
Страница 11: ...9 Memo ...
Страница 47: ...45 CHAPTER 2 SYSTEM CONFIGURATION 2 2 1 General Image of System 1 When connected to a CPU module ...
Страница 176: ...174 ...
Страница 264: ...262 ...
Страница 266: ...264 ...
Страница 267: ...265 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 268: ...266 ...
Страница 269: ...267 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 270: ...268 ...
Страница 271: ...269 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 272: ...270 Z ABRST1 instruction execution ...
Страница 273: ...271 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 278: ...276 ...
Страница 279: ...277 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 280: ...278 ...
Страница 281: ...279 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 282: ...280 ...
Страница 283: ...281 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 284: ...282 ...
Страница 285: ...283 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 286: ...284 ...
Страница 287: ...285 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Страница 316: ...314 Memo ...
Страница 685: ...683 APPENDICES A Appendix 1 Function Update Appendix 1 1 Function comparison Memo ...
Страница 738: ...736 Memo ...
Страница 806: ...804 5 LD75D2 Unit mm 6 LD75D4 Unit mm 45 4 90 4 95 4 45 45 DIN rail center 45 4 90 4 95 4 45 45 DIN rail center ...
Страница 817: ......