20. DIRECT CONNECTION TO CPU
20.2 System Configuration
20 - 9
20
DIRE
CT
CONNECTION T
O
CPU
21
COMP
U
T
E
R
LINK
CONNECTION
22
ETHE
R
N
E
T
CONNE
C
T
ION
23
CC-L
ink
CON
NE
CT
ION
(V
ia
G
4)
24
INV
E
R
T
ER
CONNECTION
25
SER
VO
A
M
PLI
F
IE
R
C
O
NNECTION
26
ROBOT
CONTROLLE
R
CONNECTION
27
CNC CONNE
C
T
ION
When connecting to FX
1S
, FX
1N
, FX
2N
, FX
1NC
, FX
2NC
(RS-232 connection)
*1
The function expansion board to be used differs according to the type of the FXCPU.Select the function expansion board from the
following table.
*2
When using function expansion boards or function adapters, confirm the communication settings.
■
Connection to FXCPU(2)When connecting with function extension board or communication special
When connecting to FX
3G
, FX
3S
, FX
3GE
(RS-422 connection)
*1
When the function expansion board (communication board) and the function adapter are connected, a GOT and a peripheral
such as a PC with GX Developer installed can be connected to them individually.
*2
When using function expansion boards or function adapters, confirm the communication settings.
■
Connection to FXCPU(2)When connecting with function extension board or communication special
PLC
Connection cable
Connector
conversion box
External cable
GOT
Model
Total
distance
Number of
connectable
equipment
Model
name
Function
expansion
board
*1*2
Function
adapter
*2
Commu
nication
Type
Cable model
Connection diagram
number
FX
1S
FX
1N
FX
2N
FX
1N
-232-BD
FX
2N
-232-BD
-
RS-232
GT01-C30R2-9S(3m)
or
GT16H-CNB-42S
GT16H-C30-42P(3m)
6m
1 GOT for
1 function
expansion
board
FX
1N
-CNV-BD
FX
2N
-CNV-BD
FX
2NC
-
232ADP
RS-232
GT01-C30R2-9S(3m)
or
GT16H-CNB-42S
GT16H-C30-42P(3m)
6m
1 GOT for
1 function
adapter
FX
0N
-232ADP
RS-232
GT01-C30R2-25P(3m)
or
GT16H-CNB-42S
GT16H-C30-42P(3m)
6m
FX
1NC
FX
2NC
-
FX
2NC
-
232ADP
RS-232
GT01-C30R2-9S(3m)
or
GT16H-CNB-42S
GT16H-C30-42P(3m)
6m
FX
0N
-232ADP
RS-232
GT01-C30R2-25P(3m)
or
GT16H-CNB-42S
GT16H-C30-42P(3m)
6m
Item
Function expansion board to be used
When connecting to FX
1N
or FX
1S
Series
When connecting to FX Series
For RS-232 communication
FX
1N
-232-BD
FX
2N
-232-BD
When the function adapter is used
FX
1N
-CNV-BD
FX
2N
-CNV-BD
PLC
Connection cable
Connector
conversion box
External cable
GOT
Model
Total
dista
nce
Number of
connectable
equipment
*1
Model
name
Function
expansion
board
*2
Function
adapter
*2
Commun
ication
type
Cable model
FX
3G
FX
3S
FX
3GE
-
-
RS-422
GT01-C10R4-8P(1m)
GT01-C30R4-8P(3m)
GT01-C100R4-8P(10m)
GT16H-CNB-42S
GT16H-C30-42P(3m)
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
13m
1 GOT for 1 PLC
built-in port
FX
3G
-422-BD
-
RS-422
GT01-C10R4-8P(1m)
GT01-C30R4-8P(3m)
GT01-C100R4-8P(10m)
GT16H-CNB-42S
GT16H-C30-42P(3m)
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
13m
1 GOT for
1 function
expansion board
Содержание GT16
Страница 1: ......
Страница 2: ......
Страница 46: ...1 4 1 OVERVIEW 1 1 Features ...
Страница 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Страница 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Страница 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Страница 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Страница 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Страница 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Страница 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Страница 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Страница 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Страница 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Страница 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Страница 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Страница 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Страница 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Страница 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Страница 422: ...REVISIONS 4 ...
Страница 425: ......
Страница 426: ......
Страница 427: ......
Страница 428: ......
Страница 470: ......
Страница 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Страница 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Страница 584: ......
Страница 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Страница 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Страница 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Страница 648: ......
Страница 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Страница 660: ......
Страница 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Страница 676: ......
Страница 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Страница 744: ......
Страница 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Страница 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Страница 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Страница 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Страница 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Страница 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Страница 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Страница 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Страница 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Страница 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Страница 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Страница 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Страница 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Страница 1131: ...MICROCOMPUTER CONNECTION 61 MICROCOMPUTER CONNECTION SERIAL 61 1 62 MICROCOMPUTER CONNECTION ETHERNET 62 1 ...
Страница 1132: ......
Страница 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Страница 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Страница 1272: ......
Страница 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Страница 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Страница 1294: ......
Страница 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Страница 1302: ...REVISIONS 4 ...
Страница 1305: ......
Страница 1306: ......