
31. FA TRANSPARENT FUNCTION
31.7 Precautions
31 - 63
28
ENERG
Y MEAS
URIN
G UNIT
/
ELECT
RIC M
UL
TI-
MEAS
UR
ING
INSTRUMENT
CO
NNECT
IO
N
29
GO
T
MUL
T
I-
DRO
P
CONNECTION
30
M
U
LT
I-
CH
A
N
NE
L
FUNCTION
31
FA
TRANS
P
ARENT
FUNCTION
32
CONNECTION
T
O
IA
I
ROBOT CONT
ROLLE
R
33
C
O
NNECTION T
O
OMRON PLC
34
CO
N
N
EC
TI
O
N
T
O
O
M
R
O
N T
E
MPER
TU
RE
C
O
NT
ROL
LE
R
35
CONNECTION T
O
KEY
ENCE PLC
31.7.2 When using GX Works3, GX
Works2, GX Developer
When connecting to QCPU (A mode)
When connecting to QCPU (A mode), set the PLC type
to "A4UCPU" or "QCPU (A mode)" on GX Developer.
When [monitor conditions] have been set on
GX Works3, GX Works2, GX Developer
(1) Monitoring performance of the GOT is temporarily
suspended.
(2) The GOT cannot respond to the touch switch operation
and numerical/ascii inputs.
(3) Writing to PLC results in a system alarm occurrence
and displays the message, "315 Device writing error.
Correct device.".
(4) While setting the monitor conditions, do not perform
any operation which makes the GOT restart (e.g.
downloading project data, changing utility data).
Doing so may display a system alarm, "402
Communication timeout. Confirm communication
pathway or modules." when the GOT restarts.
When the monitor conditions setting for the PLC CPU
has not been cancelled, reconnect GX Developer, GX
Works2 to cancel the setting. (An error may be output
when the monitor conditions setting is cancelled.)
(5) When the time check of GX Works3, GX Works2, GX
Developer is set to 30 seconds or more in the monitor
condition settings, the message "402 Communication
timeout. Confirm communication pathway or modules."
may appear.
Set the time check time of GX Developer and GX
Works2 to 30 seconds or less.
When exiting GX Works3, GX Works2, GX
Developer
For 45 seconds after GX Works3, GX Works2, GX
Developer have been exited, the GOT continues
monitoring at the same speed as when the FA
transparent function is working.
When performing [Read to PLC], [Write to
PLC] and other file operations on GX
Works3, GX Works2, GX Developer
If any of the following GOT functions is executed during
the file operation such as [Read to PLC] or [Write to
PLC], an error may occur on the GOT, GX Works3, GX
Works2, GX Developer.
In this case, take the following corrective action:
• File reading in the ladder monitor function for
MELSEC-Q
• Read/write of values of the file register specified for
the recipe function
*1
The numerical indicates the system alarm No.
• Reading TC monitor set value in the system monitor
function
• Reading the special module monitor CPU
Malfunction log
Error messages
on GOT
Corrective
action on GOT
side
Error messages
on GX Works3,
GX Works2,
GX Developer
Corrective
action on
GX Works3,
GX Works2,
GX Developer
The file is not
found.
With no file
operation being
executed on GX
Developer or
GX Works2, re-
execute the file
reading.
File access
failure.
Please retry.
With no file
reading being
executed in the
ladder monitor
function for
MELSEC-Q,
re-execute the
file operation.
Error messages
on GOT
Corrective
action on GOT
side
Error messages
on GX Works3,
GX Works2,
GX Developer
Corrective
action on
GX Works3,
GX Works2,
GX Developer
358 PLC file
access failure.
Confirm PLC
drive.
*1
With no file
operation on
GX Works3, GX
Works2, GX
Developer, turn
ON the trigger
device for the
recipe function
again.
File access
failure.
Please retry.
Execute the
file access
operation
again with the
recipe in-
process signal
in GOT system
information
OFF.
PLC file system
error. Unable to
communicate
with PLC.
Error messages
on GOT
Corrective
action on GOT
side
Error messages
on GX Works3,
GX Works2,
GX Developer
Corrective
action on
GX Works3,
GX Works2,
GX Developer
No message is
displayed.
(The TC set
value space is
blank.)
With no file
operation being
executed on GX
Works3, GX
Works2, GX
Developer, re-
execute the TC
monitor.
File access
failure.
Please retry.
With no TC set
value being
read, re-
execute the file
operation.
Error messages
on GOT
Corrective
action on GOT
side
Error messages on
GX Works3,
GX Works2,
GX Developer
Corrective
action on
GX Works3,
GX Works2,
GX Developer
Communication
error
With no file
operation being
executed on GX
Works3,
GX Works2,
GX Developer
re-execute the
CPU malfunction
log reading.
File access
failure.
Please retry.
With no special
module
monitor CPU
malfunction log
being read,
execute the file
operation.
Содержание GT16
Страница 1: ......
Страница 2: ......
Страница 46: ...1 4 1 OVERVIEW 1 1 Features ...
Страница 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Страница 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Страница 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Страница 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Страница 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Страница 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Страница 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Страница 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Страница 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Страница 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Страница 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Страница 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Страница 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Страница 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Страница 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Страница 422: ...REVISIONS 4 ...
Страница 425: ......
Страница 426: ......
Страница 427: ......
Страница 428: ......
Страница 470: ......
Страница 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Страница 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Страница 584: ......
Страница 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Страница 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Страница 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Страница 648: ......
Страница 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Страница 660: ......
Страница 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Страница 676: ......
Страница 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Страница 744: ......
Страница 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Страница 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Страница 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Страница 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Страница 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Страница 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Страница 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Страница 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Страница 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Страница 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Страница 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Страница 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Страница 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Страница 1131: ...MICROCOMPUTER CONNECTION 61 MICROCOMPUTER CONNECTION SERIAL 61 1 62 MICROCOMPUTER CONNECTION ETHERNET 62 1 ...
Страница 1132: ......
Страница 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Страница 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Страница 1272: ......
Страница 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Страница 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Страница 1294: ......
Страница 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Страница 1302: ...REVISIONS 4 ...
Страница 1305: ......
Страница 1306: ......