33. CONNECTION TO OMRON PLC
33.3 Ethernet Connection
33 - 25
28
ENERG
Y MEAS
UR
ING
UNIT
/
ELECT
RIC M
UL
TI-
MEASURING
INSTRU
M
ENT
CO
NNECT
IO
N
29
GO
T
MUL
T
I-
DRO
P
CONNECTION
30
MUL
T
I-CHA
N
N
E
L
FUNCT
ION
31
F
A
TRANS
P
ARENT
FUNCTION
32
CO
NNE
C
TI
ON T
O
IA
I
ROBOT CON
T
ROLLER
33
CONNECTION
T
O
OMRON PLC
34
CO
N
N
EC
TI
O
N
T
O
OM
RON
T
E
MPERA
TURE
C
O
NT
ROL
LE
R
35
CONNECTION T
O
KEY
ENCE PLC
33.3.3 PLC side setting
POINT
POINT
POINT
OMRON PLC
For the communication between OMRON PLC and GOT, use the FINS communication.
For the FINS communication, the node must be specified according to the realm of FINS. However, for the
Ethernet network, the data transfer according to the IP address is required.
• Automatic conversion method (dynamic)
• Automatic conversion method (static)
• IP address table conversion method
• Combined method
The following four methods are available for converting the FINS node address to the IP address.
For details of OMRON PLCs, refer to the following manual.
OMRON PLC user's Manual
Communication settings
For the PLC communication setting, set with a software for programming apparatus (CX-Programmer Ver.3.20 or
later).
(1) CX-Programmer setting
*1
Set the same [IP address] and [FINS UDP Port] settings as that of [IP address] and [Port No.] of the GT Designer3 Ethernet
setting.
*2
The Node IP Address dynamically change function is available only when the Ethernet module to be used is Ver.1.3 or later.
For the setting, set in the module setting of CX-Programmer Ver.5.0 or later or in the WEB function.
For details of Node IP Address dynamically change, refer to the following manual.
OMRON PLC user's Manual
*3
Set the same lowermost bit of the [IP address] setting as that of the node setting switch of the module.
*4
Set the same [GOT Port No. (Communication)] In Communication detail settings as that of [Port No.] of the Ethernet setting.
*5
Set the same lowermost bit of the [GOT IP address] in Communication detail settings as that of [GOT PLC No.].
*6
Set the same lowermost bit of the [GOT IP address] and [GOT PLC No.] in Communication detail settings of GT Designer3 as
that of [IP address table].
Item
Setting range
Automatic conversion method
(dynamic)
Automatic conversion method
(static)
*4*5
IP address table method
*4*6
Combined method
*4*6
Ethernet
Unit
CPU
highly-
functional
Unit
Global
All 1 (Default)
All 1 (Default)
All 1 (Default)
All 1 (Default)
IP Address
*1
[192]. [168]. [0]. [1]
*3
[192]. [168]. [0]. [1]
*3
[192]. [168]. [0]. [1]
[192]. [168]. [0]. [1]
Subnet
Mask
[255]. [255]. [255]. [0]
[255]. [255]. [255]. [0]
[255]. [255]. [255]. [0]
[255]. [255]. [255]. [0]
FINS UDP
port
*1
9600
9600
9600
9600
IP address
conversion
Automatic conversion method
(dynamic)
Automatic conversion method
(static)
IP address table method
Combined method
IP address table
-
-
10 [192]. [168]. [0]. [1]
11 [192]. [168]. [0]. [18]
10 [192]. [168]. [0]. [1]
Transmission
speed
Automatic detection (Default)
Automatic detection (Default)
Automatic detection (Default)
Automatic detection (Default)
Node IP
Address
dynamically
change
*2
Change dynamically (Default)
Change dynamically (Default)
Change dynamically (Default)
Change dynamically (Default)
Содержание GT16
Страница 1: ......
Страница 2: ......
Страница 46: ...1 4 1 OVERVIEW 1 1 Features ...
Страница 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Страница 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Страница 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Страница 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Страница 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Страница 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Страница 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Страница 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Страница 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Страница 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Страница 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Страница 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Страница 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Страница 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Страница 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Страница 422: ...REVISIONS 4 ...
Страница 425: ......
Страница 426: ......
Страница 427: ......
Страница 428: ......
Страница 470: ......
Страница 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Страница 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Страница 584: ......
Страница 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Страница 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Страница 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Страница 648: ......
Страница 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Страница 660: ......
Страница 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Страница 676: ......
Страница 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Страница 744: ......
Страница 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Страница 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Страница 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Страница 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Страница 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Страница 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Страница 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Страница 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Страница 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Страница 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Страница 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Страница 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Страница 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Страница 1131: ...MICROCOMPUTER CONNECTION 61 MICROCOMPUTER CONNECTION SERIAL 61 1 62 MICROCOMPUTER CONNECTION ETHERNET 62 1 ...
Страница 1132: ......
Страница 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Страница 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Страница 1272: ......
Страница 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Страница 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Страница 1294: ......
Страница 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Страница 1302: ...REVISIONS 4 ...
Страница 1305: ......
Страница 1306: ......