SPM address
Data type
R/W
Function
B22
BYTE
R
Major part of version number (1.0)
B23
BYTE
R
Minor part of version number (1.0)
D6
UDINT
R
Serial number (board number)
W14
INT
R
Counter will be increased for every measured value.
D8
DINT
R
Current gross weight
D9
DINT
R
Current net weight
D10
DINT
R
Current tare weight
D11
DINT
R
Current gross/net weight selected with X72
D14
DINT
R
Max weight (FSD)
D15
DINT
R
Min weight
D16
DINT
R
Report: Gross weight
D17
DINT
R
Report: Net weight
D18
DINT
R
Report: Tare weight
D19
DINT
R
Report: Sequence number
D20
DINT
R
Application-independent: Flow value (weight change•100/minute)
if no BCD card is installed.
Standard only: BCD value for "transparent" mode
D21
DINT
R
Report: Date
D22
DINT
R
Report: Time, BCD display
D23
DINT
R
Activity counter, test of communication with device
D24
DINT
R
Standard only: Limit: Limit 1 on
D25
DINT
R
Standard only: Limit: Limit 1 off
D26
DINT
R
Standard only: Limit: Limit 2 on
D27
DINT
R
Standard only: Limit: Limit 2 off
D28
DINT
R
Standard only: Limit: Limit 3 on
D29
DINT
R
Standard only: Limit: Limit 3 off
D30
UDINT
R/W
Standard only: Analog output for "transparent" mode
D31
DINT
R/W
Write the value in the fixed tare memory.
B144
X1152
X1153
X1154
X1155
BYTE
BOOL
BOOL
BOOL
BOOL
R
R
R
R
R
EasyFill only:
Batching status 1
Batching mode active
Batching mode ready/idle
Batching mode error
Batching mode in setup
13 SPM