Switch for input
PR 5510/09 block diagram
Factory setting:
S102
Factory setting:
S101
An external power supply is required: PIN 1 (Uext), reference po-
tential PIN 26 (GND)
4.6.6.1
Outputs
The outputs for PR 5510/09 (PIN 2
24) work as a reference potential and open collectors
with a shared ground.
A non-active output is highly resistant.
A voltage of 0.9 V is applied to an active output via GND.
The load to be connected is between the outputs (PIN 2
24, 25) and Uext (PIN 1).
X3 Process Indicator PR 5410
4 Device installation
Minebea Intec
EN-82