8
1.1.4 Wiring
1.1.5 Operation
Danger
1.
Allow only qualified electrical engineers to install the drive. Failure to comply could cause
electrical shocks to personnel or damage to the drive.
2.
Ensure the power supply is off when connecting. Failure to comply could cause electrical
shocks.
3.
Ensure the ground terminal PE is properly wired. Failure to comply could cause electrical
shocks from the drive cover. Therefore ground the drive and motor for personnel safety.
4.
Do not touch the main circuit terminal. Keep the main circuit off drive cover to avoid
electrical shocks.
5.
The terminal for braking resistor is B1 and B2. Do not connect it to any other terminals.
Failure to comply could cause a fire.
Warning
1.
Do not connect three-phase power supply to terminals U, V and W. Failure to comply
could damage the drive.
2.
An output reactor is recommended when the cable connecting between the drive and
motor is over 100 meters. Failure to comply could result in drive damage with
overcurrent caused by over-distributed capacitance.
3.
Never connect the output terminals to capacitors or unapproved LC/RC filters. Failure to
comply could damage the drive components.
4.
Separate the drive main circuit cables and control circuit cables. Failure to comply could
cause interference to the control signals
5.
Ensure the phase of power supply and rated voltage match the label on the drive. Failure
to comply could drive damage.
Danger
1.
Connect the power after completion of wiring and closing the front cover. Opening the
front cover when the power is on could cause electrical shocks.
2.
Keep other personnel off the equipment when setting the drive fault restart and
momentary power loss restart functions. Failure to comply could cause damage to the
personnel and equipment.
3.
Once the drive is powered, the terminals are live even when drive is not in operation.
Touching the terminals could cause electrical shocks.
Содержание EVO 6800 Series
Страница 1: ...MANUAL Compact Vector Drive EVO 6800 Series...
Страница 33: ...33 34 2 36 0 2 8 93 0...
Страница 35: ...35 4 2 Main Circuit...
Страница 41: ...41 4 3 Control Circuit...
Страница 260: ...260 Above panel display value excluding the decimal point units please according to actual user unit conversion...