124
d2- 02 Motor No-Load Current
Sets the motor no-load current when running at no-load voltage and rated frequency. This will
be set automatically during Auto-Tuning. This can also be set according to the no-load current
listed on the motor test report. Contact the motor manufacturer for a test report.
No.
Name
Setting Range
Default
d2-02
Motor No-Load Current
0.0 A to [d2-00] A
( exclude d2-00)
Determined by o2-03,
A1-06
Note: If the maximum motor capacity the drive can run is less than 11kW, it will be displayed in units of 0.1A. The
maximum motor capacity the drive can run is determined by A1-06 (ND/HD Mode). Refer to Ch 2.4 on page 15?.
d2- 03 Number of Motor Poles
Sets the number of motor poles. This will be set automatically during Auto-Tuning.
No.
Name
Setting Range
Default
d2-03
Number of Motor Poles
2 to 48
4
d2- 04 Motor Line-to-Line Resistance
Sets the line-to-line resistance. This will be set automatically during Auto-Tuning. Do not mix
motor line-to-line resistance with resistance for PM motors.
If Auto-Tuning cannot be performed, contact the motor manufacturer for the test report. Use
the line-to-line resistance listed in the rest report to calculate the line-to-line resistance by the
following formula.
·
E-type insulation: the resistance value (Ω) listed on the test report at 75°C × 0.92
·
B-type insulation: the resistance value (Ω) listed on the test report at 75°C × 0.92
·
F-type insulation: the resistance value (Ω) listed on the test report at 115°C × 0.87
No.
Name
Setting Range
Default
d2-04
Motor Line-to-Line Resistance
0.000 to 65.000 Ω
<1>
Determined by o2-03,
A1-06
d2- 05 Motor Leakage Inductance
Sets the voltage drop caused by the motor leakage inductance relative to the motor rated
frequency and current. This will be set automatically during Auto-Tuning.
No.
Name
Setting Range
Default
d2-05
Motor Leakage Inductance
0.00 to 650.00 mH
Determined by o2-03,
A1-06
d2- 06 Motor Rotor Resistance