138
65 : DC Braking
Stops the motor during deceleration. When a Run command or Jog command is entered, the
DC braking will be removed as illustrated in the following figure. Refer to b2 (DC Braking) for
details.
Output
frequency
Run
command
DC braking
command
ON
ON
OFF
OFF
OFF
OFF
DC braking
DC Braking
Start Level
( b2-00 )
DC braking
Figure 6.52 DC Braking Operation
66 to 68: Retain
69 : Drive Enabled
The drive does not accept any Run command until the input terminal closes. When the input
terminal is open, the keypad will display “DNE”.
If a Run command is entered before the assigned terminal closes, then drive will not run until
the Run command is cycled. If the terminal is open during run, the drive will stop according to
b1-02 (Stopping Method Selection). Refer to b1-02 for details.
70 to 73: Retain
74 : S7 is set to pulse input or PWM
E2 Multi-Function Digital Output
E2- 00 to E2- 02 Relay 1/ Relay 2 And D1/ DC Function Selection
The drive has four multi-function output terminals. Assign the functions to E2-00 to
E2-02according to Table 6.20.
No.
Parameter Name
Setting Range
Default
E2-00
Relay 1 Function Selection
0~49/100~149
0: During run
E2-01
Relay 2 Function Selection
0~49/100~149
11: Fault
E2-02
D1/DC Function Selection (Open
Collector)
0~49/100~149
1: Zero Speed
Table 6.20 Multi-Function Output Terminal Settings
Note1. If reverse the digital output terminal output function, parameter setting can be selected for