149
E2-00 to E2-03
(Multi-Function
Digital Output)
ON
OFF
E2-05
(Watt Hour Output Unit )
OFF
Integral power
(every 100 ms )
0.2 s
Figure 6.61 Watt Hour Output Operation
The drive has two multi-function analog inputs (A1 and A2). Set the terminal A1 and A2
according to Table 6.21.
E2- 06 Relay 1 On Delay
No.
Name
Setting Range
Default
E2-06
Relay 1 On Delay
0.0 ~ 3600.0 s
0.0 s
E2- 07 Relay 1 Off Delay
No.
Name
Setting Range
Default
E2-07
Relay 1 Off Delay
0.0 ~ 3600.0 s
0.0 s
E2- 08 Relay 2 On Delay
No.
Name
Setting Range
Default
E2-08
Relay 2 On Delay
0.0 ~ 3600.0 s
0.0 s
E2- 09 Relay 2 Off Delay
No.
Name
Setting Range
Default
E2-09
Relay 2 Off Delay
0.0 ~ 3600.0 s
0.0 s
Example 1: Setting E2- 06/ E2- 07/ E2- 08/ E2- 09 > 0.0s。