SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4. Check backplane cable connection.
5.
Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
•
806f050d-0410ffff : Array [ComputerSystemElementName] is in critical condition. (Ext Drive)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0410ffff or 0x806f050d0410ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4. Check backplane cable connection.
5.
Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
•
806f0513-2582ffff : A PCI SERR has occurred on system [ComputerSystemElementName]. (PCIs)
This message is for the use case when an implementation has detected a PCI SERR.
514
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide
Содержание HX1310
Страница 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Страница 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 992: ...Taiwan BSMI RoHS declaration 978 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 1001: ......
Страница 1002: ......