associated with power rail errors” on page 78, restarting the server each time, until the cause
of the overcurrent condition is identified.
Table 20. Components associated with power rail errors
Pwr rail error in the IMM event log
Components
Pwr rail 1 error
• Microprocessor 1
Pwr rail 2 error
• Microprocessor 2
Pwr rail 3 error
• DIMMs 1 through 12
• Fan 3
Pwr rail 4 error
• Fan 5
• Fan 6
• DIMMs 13 through 24
Pwr rail 5 error
• Fan 7
• Fan 8
• SAS/SATA hard disk drives and USB
Pwr rail 6 error
• Optional cable for VGA external power
• PCI-E and x16 (maximum expansion is 4 adapter cards)
• PCI-E hard disk drives
Pwr rail 7 error
• Fan 1
• Fan 2
d.
Replace the identified component.
Step 5.
Remove the adapters and disconnect the cables and power cords to all internal and external
devices until the server is at the minimum configuration that is required for the server to start (see
“Power-supply LEDs” on page 54 for the minimum configuration).
Step 6.
Reconnect all power cords and turn on the server. If the server starts successfully, reseat the
adapters and devices one at a time until the problem is isolated.
If the server does not start from the minimum configuration, see “Power-supply LEDs” on page 54 to replace
the components in the minimum configuration one at a time until the problem is isolated.
Solving Ethernet controller problems
The method that you use to test the Ethernet controller depends on which operating system you are using.
See the operating-system documentation for information about Ethernet controllers, and see the Ethernet
controller device-driver readme file.
Try the following procedures:
• Make sure that the correct device drivers, which come with the server are installed and that they are at
the latest level.
• Make sure that the Ethernet cable is installed correctly.
– The cable must be securely attached at all connections. If the cable is attached but the problem
remains, try a different cable.
– If you set the Ethernet controller to operate at 100 Mbps, you must use Category 5 cabling.
– If you directly connect two servers (without a hub), or if you are not using a hub with X ports, use a
crossover cable. To determine whether a hub has an X port, check the port label. If the label contains
an X, the hub has an X port.
78
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide
Содержание HX1310
Страница 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Страница 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 992: ...Taiwan BSMI RoHS declaration 978 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 1001: ......
Страница 1002: ......