May also be shown as 800701142201ffff or 0x800701142201ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix:
PLAT
ID:
0520
User Response
1. Complete the administrative tasks that require the TPM physical presence switch to be in
the ON position.
2. Restore the physical presence switch to the OFF position.
3.
Reboot the system.
4. (Trained technician only) If the error continues, replace the planar.
•
80070121-0782ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (PCIe Dev Status)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701210782ffff or 0x800701210782ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix:
PLAT
ID:
0520
User Response
334
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide
Содержание HX1310
Страница 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Страница 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 992: ...Taiwan BSMI RoHS declaration 978 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 1001: ......
Страница 1002: ......