• Connector 1 supports low-profile card.
• Connector 2 supports low-profile or half-length, full-height cards.
For a list of the supported PCI riser card assembly configurations, go to “Replacing a PCI riser-card
assembly” on page 121 or “Replacing an adapter” on page 126.
Electrical input:
• Sine-wave input (50 - 60 Hz) required
• For 750W/900W Platinum power supply
– Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
– Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
• Input kilovolt-amperes (kVA), approximately:
– Minimum: 0.179 kVA
– Maximum: 1.188 kVA
Notes:
– Power consumption and heat output vary depending on the number and type of optional features
installed and the power-management optional features in use.
– The noise emission level stated is the declared (upper limit) sound power level, in bels, for a
random sample of machines. All measurements are made in accordance with ISO 7779 and
reported in conformance with ISO 9296. Actual sound-pressure levels in a given location might
exceed the average values stated because of room reflections and other nearby noise sources.
The noise emission level stated in the declared (upper limit) sound-power level, in bels, for a
random sample of system.
Hot-swap fans:
• One microprocessor: five dual-motor hot-swap fans 1, 2, 3, 5, 7
• Two microprocessors: seven dual-motor hot-swap fans 1, 2, 3, 5, 6, 7, 8
Note:
The fan 4 slot is always occupied by a fan filler.
Power supply:
• Up to two hot-swap power supplies for redundancy support
– 750-watt ac 80 PLUS Platinum
– 900-watt ac 80 PLUS Platinum
Note:
Power supplies in the server must be with the same power rating or wattage.
Acoustical noise emissions:
• Sound power, idling: 6.5 bels maximum
• Sound power, operating: 6.5 bels maximum
Note:
The PCIe options supported in this system vary greatly in function, power draw, and required
cooling. Any increase in cooling required by these options will result in increased fan speed and
produced sound power level. The actual sound pressure levels measured in your installation depend
upon a variety of factors, including the number of racks in the installation; the size, materials, and
configuration of the room; the noise levels from other equipment; the room ambient temperature and
pressure, and employees’ location in relation to the equipment.
Heat output:
Approximate heat output:
The Lenovo Converged HX Series server
7
Содержание HX1310
Страница 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Страница 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 992: ...Taiwan BSMI RoHS declaration 978 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 1001: ......
Страница 1002: ......