3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
•
806f060d-0404ffff : Array [ComputerSystemElementName] has failed. (Drive 4)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0404ffff or 0x806f060d0404ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
•
806f060d-0405ffff : Array [ComputerSystemElementName] has failed. (Drive 5)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0405ffff or 0x806f060d0405ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
521
Содержание HX1310
Страница 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Страница 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 992: ...Taiwan BSMI RoHS declaration 978 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 1001: ......
Страница 1002: ......