180-801-000 : Check-point Panel Test Aborted
Check-point Panel Test Aborted. BMC is unable to verify that the operator information panel cable is
connected.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Inspect and reseat operator information panel cable at both ends.
2. Verify that the Baseboard Management Controller (BMC) is working.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
•
180-901-000 : Check-point Panel Test Failed
Check-point Panel Test Failed. Operator reported incorrect display.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps: