Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0522
User Response
None
•
80070228-2e01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (IPMB IO Error)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702282e01ffff or 0x800702282e01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0522
User Response
If the specified sensor is IPMB IO Error, Me Error or ME Flash Error, complete the following steps
until the problem is solved:
1. Restart IMM. If the error still appears, proceed step 2.
2. Update the firmware (UEFI and IMM) to the latest level. If the error still appears, proceed step 3.
3.
Replace the node.
ME Error : ME Flash Error :
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
347
Содержание HX1310
Страница 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Страница 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 992: ...Taiwan BSMI RoHS declaration 978 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 1001: ......
Страница 1002: ......