80070208-0a02ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (PS 2 Therm Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702080a02ffff or 0x800702080a02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix:
PLAT
ID:
0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2.
Use the Lenovo Power Configurator utility to ensure current system power
consumption is under limitation. For more information and to download the utility, go to
https://www.ibm.com/support/entry/myportal/docdisplay?lndocid=LNVO-PWRCONF.
3. Replace power supply n. (n = power supply number)
•
8007020d-2582ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (RAID Vol State)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020d2582ffff or 0x8007020d2582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
342
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide
Содержание HX1310
Страница 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Страница 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 992: ...Taiwan BSMI RoHS declaration 978 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Страница 1001: ......
Страница 1002: ......