Step 5.
Insert the fan into the fan slot in the fan assembly bracket and press it down until it is seated
correctly in the slot and the fan connector is installed correctly to the connector on the system
board.
Figure 55. Fan installation (2)
Note:
Make sure that the newly-installed fan aligns horizontally with other correctly-seated fans
for proper installation.
Step 6.
Reinstall the cover (see “Replacing the cover” on page 105).
Step 7.
Slide the server into the rack.
Removing a hot-swap ac power supply
Use this information to remove a hot-swap ac power supply.
When you remove or install a hot-swap power supply, observe the following precautions.
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
1
2
Removing and replacing components
131